Assessment of prosthetic complications of customized and electrical welded frameworks in maxillary implant fixed detachable prosthesis (split mouth study)

Document Type : Original articles

Author

prosthodontic department faculty of dentistry Cairo university

Abstract

This study was conducted to asses prosthetic complications, passive fit, chair side numbers and duration .cost and cost effectiveness of customized and electrical welded frameworks in maxillary implant fixed detachable prosthesis.
Methodology:
This split mouth study was performed on six completely edentulous patients received maxillary fixed detachable prosthesis, where Group I: customized framework while Group II: electric welded framework.. During prosthetic construction period for both frameworks, passive fit were done using gone screw test Assessments of prosthetic complications were evaluated 3 and 6 month later. Numbers and duration of visits .total cost and cost effectiveness were calculated
Result
Comparison between both groups revealed insignificant difference regarding all prosthetic complications. after 3 months and 6 months. The Evaluation of the passive fit revealed that in customized framework was significantly higher than electric welded group in yes, while was significantly lower in no
In group I C/E ratio (93.5) was higher than group II (85.7), as the total cost in group I was (9350), while in group II was (7150)..In number of needed visits, group I (6.83 ± 0.75) was significantly higher than group II (3.16 ±0.41) as P <0.05.
Conclusion
Maxillary fixed detachable prosthesis supported by customized or electric welded framework show no difference regarding the prosthetic complication while the electric welded framework shows highly passive fit when compared to the customized one .the cost .cost effectiveness, numbers of visits are lower and visits duration is shorter in electric welded framework when compared to the customized one